Found my spare contactor, and swapped it in. No change :-(
Steve
On Wed, 17 Jul 2019, jlantonucci comcast net wrote:
Have you tried replacing the contactor? I've seen older one act up like
this.
Sent from my T-Mobile 4G LTE device
------ Original message------
From: Steve Gaarder
Date: Tue, Jul 16, 2019 3:32 PM
To: elec-trak cosmos phy tufts edu;
Cc: scarecrow gmail com;
Subject:(ET) Strange Alltrax behavior
I have an E-15 with an Alltrax controller. The speed control pot is on a
throttle lever and the foot switch is controlled by a s
eparate switch. The first time I start it up it's ok. I turn on the key
switch, the contactor closes and then opens a few secon
ds later. I turn on the "foot" switch, the contactor closes, and off we
go. It's all fine till I turn off the foot switch. Aft
er that, it will not run. Turning on the key switch makes the contactor
close, again for a few seconds, but it never closes agai
n, until I let it sit turned off for 15 minutes or more.Any ideas?Steve
Gaarder_______________________________________________Ele
c-trak mailing
listElec-trak cosmos phy.tufts.eduhttps://cosmos.phy.tufts.edu/mailman/listinfo/elec-trak
_______________________________________________
Elec-trak mailing list
Elec-trak cosmos phy tufts edu
https://cosmos.phy.tufts.edu/mailman/listinfo/elec-trak