[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ET) Nothing works!



Nope, I need to amend my last email.  I get 37 V when the power disconnect is not engaged.  I had the key off :)
 
-------------- Original message --------------
From: Jim Coate <jbc_lists_NO_REPLY coate org>

> Progress!
>
> Check your main disconnect - is it really making a good connection? The
> fuel gauge needs to stay on!
>
> Check the "safeties" - when the key switch is turned on, brakes off,
> seat switch closed does one of the small control relays at the top activate?
>
>
> paul mitchell2007 comcast net wrote:
> > Okay, no blown fuses and the lights and lift motor work! The fuel gauge
> > moved just shy of green and then immediately fell dead. The main motor
> > is not engaging though when the throttle is moved forward or back. I'm
> > still getting 0 volts across the 2 small screws on the 1F relay with the
> > speed control forward. Any thoughts on tracing that problem ?
> >
>
>
> --
> Jim Coate, Spencertown, New York
>
> = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
> NOTE: Mail sent to the "NO_REPLY" address will *not* reach me.
> To send me a private message, please follow the directions here:
> http://www.coate.org/contact_jim/
> = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
>
> 1998 Electric S-10, 1997 Solectria Force, 1970's Elec-Traks
> http://www.eeevee.com
>
> The Electric Tractor Store is now open!
> http://www.electrictractorstore.com