Re: (ET) current ratings for contactors? 50A enough for PTO?



Thanks, Harold and Chris!

I thought 50A had to be too low.  100A makes way more sense.  (The Kilovac 500 amp contactors Rod mentioned sound even better, but I want the braking action so SPST won't work.)

--Charlie

On Thu, Jun 22, 2017 at 1:06 PM, Christopher Zach <cz alembic crystel com> wrote:
Probably because it has to dump extra energy when going open and effectively shorting out the mower deck motors. That's a lot of energy stopping very quickly.

100a is about right for blowing snow. I don't have a shunt on that line specifically, but 300+ amps would include the drive motor shoving the thing up hill.

C



On 6/22/2017 12:11 PM, Harold Zimmerman - Clean Power Supply wrote:
  They were Prestolite contactors. I have the spec. sheet. The Normally Open contacts are rated at 100 amps and the Normally Closed at 150 amps.
  Doesn't seem right that the NO are lower than NC but the NC are Silver and the NO copper.
  Harold Zimmerman
  Clean Power Supply
  Supplier of parts for General Electric Elec-Trak, New Idea and Wheel Horse Electric Tractors.
  717-859-4234

On June 22, 2017 at 11:44am -0400, Charlie <medievalist gmail com> wrote:

I just wish I could find some kind of GE document or other resource that
actually stated the current rating of these contactors.

--Charlie

------------------------------------------------------
Sent from my MailBug email device. For info call:
1-855-MAILBUG, mailbug.com, getmailbuginfo landel com
------------------------------------------------------
_______________________________________________
Elec-trak mailing list
Elec-trak cosmos phy tufts edu
https://cosmos.phy.tufts.edu/mailman/listinfo/elec-trak


_______________________________________________
Elec-trak mailing list
Elec-trak cosmos phy tufts edu
https://cosmos.phy.tufts.edu/mailman/listinfo/elec-trak