At 12:29 PM 12/4/2007 -0500, Krug, Jeff wrote:
I would be very interested in the alltrax autopsy report. While I am all for diodes to reduce chatter in a contactor and MOV's to absorb spikes. I am rather hesitant to rely on these to protect a $300 investment. Soon or later a diode or MOV will take enough hits and fail.
A properly sized diode shouldn't fail as a result of load. Adding a resistor to help increase the decay rate of the coil current can be a good idea. It can help by increasing the separation rate of the contactor tips.