[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ET) wiring diag help needed...



This makes sence exept I didn't think anything on this tractor was wired to ground?
Anyone know?
John Briese


From: Paul and Sue Abendroth <pabendro gemair com>
To: elec-trak cosmos phy tufts edu
Subject: Re: (ET) wiring diag help needed...
Date: Sat, 17 Jul 2004 08:14:19 -0400

At 10:24 PM 7/15/04 , john briese wrote:
I eliminated too much when I did mine as well. I ended up reinstalling one of the contactors to run the pto. But I do not have the braking on the mower deck and I don't know how to get that back. It appears that I need some kind of momentary contact at shut down. Maybe someone can shed some light.
John Briese


Connect the movable contact of the relay switch to the load(motor), the normally closed contact to ground (the other motor wire) and the normally open contact to power.

ground----o
            \
             o-----load

source----o


Paul and Sue Abendroth
pabendro gemair com
our permanent address is pabendroth dma org