From: Paul and Sue Abendroth <pabendro gemair com>
To: elec-trak cosmos phy tufts edu
Subject: Re: (ET) wiring diag help needed...
Date: Sat, 17 Jul 2004 08:14:19 -0400
At 10:24 PM 7/15/04 , john briese wrote:
I eliminated too much when I did mine as well. I ended up reinstalling one
of the contactors to run the pto. But I do not have the braking on the
mower deck and I don't know how to get that back. It appears that I need
some kind of momentary contact at shut down. Maybe someone can shed some
light.
John Briese
Connect the movable contact of the relay switch to the load(motor), the
normally closed contact to ground (the other motor wire) and the normally
open contact to power.
ground----o
\
o-----load
source----o
Paul and Sue Abendroth
pabendro gemair com
our permanent address is pabendroth dma org
_______________________________________________
Elec-trak mailing list
Elec-trak cosmos phy tufts edu
https://cosmos.phy.tufts.edu/mailman/listinfo/elec-trak