[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ET) Landis controller vs. GE timer
On 3 Jan 2004 at 9:30, Jeremy Gagliardi com wrote:
> First, why is it 7.6V, and
> second, why does it always read positive?
My ^guess^ is that you're reading voltage from some kind of ground fault.
Are
you by any chance using a digital meter? They have a very high input
impedance. Try connecting a 12v taillight bulb across those leads and
then
you're apt to read zero. (And if it lights up, there ^is^ something weird
going on!)
David Roden - Akron, Ohio, USA
1991 Solectria Force 144vac
1991 Ford Escort Green/EV 128vdc
1970 GE Elec-trak E15 36vdc
1974 Avco New Idea 36vdc
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
Twenty years ago, one out of every six federal tax dollars was
generated by a corporation. That has now fallen to about one out
of every 10.