[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ET) sticky relays
- Subject: (ET) sticky relays
- From: Neil Dennis <wombat RealNS com>
- Date: Mon, 29 May 2000 14:24:59 -0400
- Sender: owner-elec-trak cosmos5 phy tufts edu
I just had an hour or so debug session with my E-12. I would drop into
first speed and keep going when I raised off the seat opening the safety
switch, also the brake would not shut down the motor. After reading
about welded solenoids here I thought OK that is the problem - so after
much checking and reading schematic, I traced to "2RTN" not traveling
far enough to open the normally open contacts. After replacing with a
spare that didn't close properly so I still had to do some adjusting,
now things work right. Incidentally, open the disconnect when fingering
around in the control box, 36 volts does bite a little. (experience)
wombat