I received my new #OP134 power disconnect switch.
It has a phenolic board attached to the switch contact
bolts, with a third stud not connected to the switch, but
has a fusible link connecting it to a switch contact.
I haven't looked at a wiring diagram to see what is
supposed to be connected to what.  My electraks'
disconnect switch was bypassed long ago, so it may
not be clear by just looking at the tractor to find what
goes where.

Any hints?  I'm too tired tonight to look at the circuit
diagram in my service manual, it'd be nice to have
someone's input as a head start for when I install
it this weekend.

Thanks.

Christopher M. Meier
MR23 http://www.geocities.com/~mr23


----- Original Message -----
From: "MR23=Christopher Meier (Mtka, MN, USA)" <mr23 worldspy net>
To: "Steve & Sandy Naugler" <snaugler earthlink net>; "Elie, Larry (L.D.)"
<lelie ford com>; "Chris Meier" <ChrisM pptvision com>;
<ThompsonG DFO-MPO GC CA>; <elec-trak cosmos5 phy tufts edu>
Sent: Saturday, April 29, 2000 12:21 PM
Subject: Re: (ET) Power Disconnect for an E12M


> I ordered a new power disconnect up from Bill this morning.
> He's charging $32.50 for a part # OP134 power disconnect.
> Steve, is this the same unit you refer to?  How long ago did
> you order it at < $20?  Thanks.
>
> Christopher M. Meier
>
>
> ----- Original Message -----
> From: "Steve & Sandy Naugler" <snaugler earthlink net>
> To: "Elie, Larry (L.D.)" <lelie ford com>; "Chris Meier"
> <ChrisM pptvision com>; <ThompsonG DFO-MPO GC CA>;
> <elec-trak cosmos5 phy tufts edu>
> Sent: Saturday, April 29, 2000 9:14 AM
> Subject: Re: (ET) Power Disconnect for an E12M
>
>
> > Larry and others
> >     My E15's switch did fail.  I then removed two different switches
from
> > non running tractors, and they were both bad.  I started swapping parts
to
> > build one good one, and none of the parts were good enough.  Bill 
> > gunn's
> new
> > style was the right choice.  I'll replace any old style leftovers with
the
> > new style from now on.
> >
> > Steve Naugler
> >
> > ----- Original Message -----
> > From: "Elie, Larry (L.D.)" <lelie ford com>
> > To: "'Steve & Sandy Naugler'" <snaugler earthlink net>; "Chris Meier"
> > <ChrisM pptvision com>; <ThompsonG DFO-MPO GC CA>;
> > <elec-trak cosmos5 phy tufts edu>
> > Sent: Friday, April 28, 2000 9:52 AM
> > Subject: RE: (ET) Power Disconnect for an E12M
> >
> >
> > > Bill also claims his has lower resistance across the device.  The
> > difference
> > > is
> > > probably trivial for power consumption, but will keep the device
> > temperature
> > >
> > > lower.  BTW, I have yet to fail an ORIGINAL switch.
> > >
> > > Larry Elie
> > >
> > >
> > > -----Original Message-----
> > > From: Steve & Sandy Naugler [mailto:snaugler earthlink net]
> > > Sent: Thursday, April 27, 2000 11:23 PM
> > > To: Chris Meier; ThompsonG DFO-MPO GC CA;
> > > elec-trak cosmos5 phy tufts edu
> > > Subject: Re: (ET) Power Disconnect for an E12M
> > >
> > >
> > > When I bought Bill Gunn's replacement disconnect it cost less than 
> > > $20
> and
> > > included a heavy circuit board to accomodate the fusible link.  I
don't
> > > think you can go wrong with the unit Bill sells.
> > >
> > > Steve Naugler
> > >
> > > ----- Original Message -----
> > > From: "Chris Meier" <ChrisM pptvision com>
> > > To: <ThompsonG DFO-MPO GC CA>; <elec-trak cosmos5 phy tufts edu>
> > > Sent: Thursday, April 27, 2000 10:59 AM
> > > Subject: RE: (ET) Power Disconnect for an E12M
> > >
> > >
> > > >
> > > > I was at a Northern Tool store last night, and they had a Pollak
brand
> > > > battery disconnect switch, rated 6-36v, 150amps, for $20.  The
ratings
> > > > are a bit low for worst-case conditions.  I don't know the price or
> > > ratings
> > > > of the newer disconnect unit that Bill Gunn sells, but you'd
probably
> be
> > > > better off using the unit he sells (based on past recommendations).
> > > >
> > > > On Thursday, April 27, 2000 6:51 AM, ThompsonG DFO-MPO GC CA
> > > > [SMTP:ThompsonG DFO-MPO GC CA] wrote:
> > > > > So, Here is the question/problem?
> > > > > I need or would like to find a Power Disconnect for an E12. At 
> > > > > the
> > > moment
> > > > I
> > > > > just have a hole on the side of the tractor where it should go 
> > > > > and
a
> > > green
> > > > > wire dangling from the Amp Meter. If you have one you are willing
to
> > > sell
> > > > > me. Please E-mail me
> > > > >
> > > > > I was digging around in my new E12 and discovered a lose green
wire
> > > under
> > > > > the dash. It came from the Amp meter. After a little while of
> staring
> > at
> > > > the
> > > > > schematics and the wiring diagrams in the manual. It finally
clicked
> I
> > > > have
> > > > > no power disconnect. Therefore I have no place to connect the Amp
> > meter.
> > > > My
> > > > > goal is to restore this ET to nearly, new condition so I need a
> power
> > > > > disconnect.
> > > > >
> > > > > Geof Thompson B. Sc.
> > > > > Data Management Engineer
> > > > > Canadian Hydrographic Service
> > > > > Central and Arctic Region
> > > > > 867 Lakeshore Road
> > > > > Burlington, Ontario
> > > > > Canada. L7R 4A6
> > > > >
> > > > >
> > > > > Phone (905) 336-4698
> > > > > Fax (905) 336-4698
> > > > > E-mail Thompsong dfo-mpo gc ca
> > > >
> > > >
> > >
> >
> >
>
>