[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ET) E20 motor at 48V



Steve,
  Without looking at the design info, that's 33% over voltage.

Gain - run faster, more acceleration

Pain - will draw more amps for higher performance, overspeed, insulation
degradation, commutation distress, running at top speed will probably
cause banding to fail if motor doesn't flashover first, transmission
damage if run too fast....basically toast. 

  DC Motors are designed using voltage and top speed as key parameters.
The number of armature conductors provides torque and commutator bars
are limited by volts per bar (between bars)......at higher voltage that
is pushed past the limit, the motor can't "commutate" the current and
blam-o....

....Walt
(ex-motor designer - can you tell?)

-----Original Message-----
From: elec-trak-bounces cosmos phy tufts edu
[mailto:elec-trak-bounces cosmos phy tufts edu] On Behalf Of SteveS
Sent: Wednesday, January 02, 2008 2:49 PM
To: et
Subject: (ET) E20 motor at 48V

Happy New Year all!

So, what's the gain and pain of running the E20 motor at 48V?

- SteveS

_______________________________________________
Elec-trak mailing list
Elec-trak cosmos phy tufts edu
https://cosmos.phy.tufts.edu/mailman/listinfo/elec-trak