[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ET) Alltrax DCX300 ET in E20



Kevin Matkowski wrote that, “Why the fuse didn’t blow, could be that you have a slow-blow fuse and the meter actually acted as a fuse to the short you created with it.”  You are probably right Kevin. I never thought of that possibility. I will search the manual for explanations of the main disconnect FU-1. Thanks for the response. Raymon