Re: (ET) Need diagnositic help on E12




- My schematic (E15) shows the motor mounted breaker cutting off everything BUT the PTO. Of course I'm still off base because then the lift wouldn't work.

- SteveS


RJ Kanary wrote:

If that circuit breaker fails, nothing but the lift will work.Since the PTO is still live, that is unlikely to be the source of trouble.

----- Original Message ----- From: "steveS" <ssawtelle verizon net>
To: "et" <Elec-trak cosmos phy tufts edu>
Sent: Tuesday, March 15, 2005 7:45 PM
Subject: Re: (ET) Need diagnositic help on E12


Check that the circuit breaker on the motor has continuity. I have seen two that open circuited because the screw adjsument had corroded away.