Yep, I have the homeowner's manual; I just didn't see a fuse and it blows 
my
mind (that's a good pun :-) that they didn't fuse an outboard outlet. What
happens if the chainsaw shorts? Melts in your hand?

That's technically a problem for me since the Elec-Trak's 20amp outlet 
plugs
directly into the outboard side of the Solarex charger. Thus if the charger
were to ever short, the full force of the tractor's battery pile would
incinerate the controller and cable. My panels and the rest of the shed's
power infrastructure are safe because they are behind a 20amp 10k AIR DC
rated fused disconnect.

I guess I'll just have to put in a second RK5 30amp disconnect box at the
plug end for the tractor, since it's technically an unfused power source.
And maybe a little sanity fuse in the tractor itself. This will make four
disconnect boxes on a simple shed.

Drat.

Chris

----- Original Message -----
From: "RJ Kanary" <rjkanary nauticom net>
To: "Christopher Zach" <czach computer org>; "David Roden (Akron OH USA)"
<roden ald net>; "Elec-trak" <elec-trak cosmos phy tufts edu>
Sent: Friday, March 08, 2002 9:15 PM
Subject: Re: (ET) Tool receptacle


> Christopher, SO-2 can be interrupted by CB-2, the one primarily intended
for
> protection in event of a diode shorting on the charger,[on the negative
> side], or CB-1, that husky, 100 to 125 Amp      Klixon® beast, that lives
on
> the traction motor,[positive side].
>        Neither can be expected to provide over current protection to that
> outlet. It is, for all intents and purposes, unfused.
>       If you have not already done so, order the Homeowner's Service
Manual
> from Tech Parts. The schematics are large enough, and clear enough, to
make
> puzzling out what goes where and why pretty straight forward.
>
>
> RJ Kanary
> Member TRNi  Since 1998
> ASE® Certified Master Auto Technician
>
> rjkanary nauticom net
>
> ----- Original Message -----
> From: "Christopher Zach" <czach computer org>
> To: "David Roden (Akron OH USA)" <roden ald net>; "Elec-trak"
> <elec-trak cosmos phy tufts edu>
> Sent: Friday, March 08, 2002 8:01 PM
> Subject: Re: (ET) Tool receptacle
>
>
> > Actually there might be a solution (there's always a solution :-)
> >
> > Way back in my pile of junk is an old DEC TC01 DecTape unit from the
> 1960's.
> > This unit used the same twist-lock plug; however it had a third round
pin
> in
> > the center.
> >
> > That was the ground. My guess is Hubbel built an ungrounded version 
> > (the
> one
> > on the ET) and one that had a hole in the center for plugs with three
> > prongs. As per NEC codes, one could plug an ungrounded device into a
> > grounded receptacle, but one could not plug a grounded device into an
> > ungrounded receptacle (think normal 2 and three prong outlets)
> >
> > Thus if I can find one of these, I could retrofit the tractor, have my
> > ground (which would be nice, because someday this system will charge 
> > off
> > 20amps of solar) and plug in ET devices when needed.
> >
> > Anyone know if that outlet is fused with a 20-30 amp fuse?
> >
> > Chris
> >
> > ----- Original Message -----
> > From: "David Roden (Akron OH USA)" <roden ald net>
> > To: "Christopher Zach" <czach computer org>
> > Sent: Friday, March 08, 2002 11:25 AM
> > Subject: Re: (ET) Tool receptacle
> >
> >
> > > On 7 Mar 2002 at 19:18, Christopher Zach wrote:
> > >
> > > > Kind of how you will not find two prong electrical outlets anymore;
> > > > installing one is pretty much a violation of current NEC codes.
> > >
> > > This is generally correct.  Note though that in an older home with
> > > ungrounded wiring, NEC prohibits installation of a 3-pin outlet as a
> > > replacement for a defective 2-pin, unless a ground is run to the box.
> > There
> > > is some question in my mind about whether installing a 2-pin outlet 
> > > is
> > > permitted or not -- this is unclear to me.  However, in such cases 
> > > the
> > code
> > > explicitly permits the installation of a GFI ~without~ ground (yes
they
> do
> > > still function that way), provided that the outlet is labeled "no
> > equipment
> > > ground."  This is what I do when replacing the outlets in my current
> home
> > > (circa 1920).
> > >
> > >
> > > David Roden - Akron, Ohio, USA
> > > 1991 Solectria Force 144vac
> > > 1991 Ford Escort Green/EV 128vdc
> > > 1970 GE Elec-trak E15 36vdc
> > > 1974 Avco New Idea 36vdc
> > > = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
> > > Thou shalt not send me any thing which says unto thee, "send this to
all
> > > thou knowest."  Neither shalt thou send me any spam, lest I smite
thee.
> > > = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
> > >
> > >
> > >
> >
> >
>
>
>