[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ET) Tool receptacle
- Subject: Re: (ET) Tool receptacle
- From: "Christopher Zach" <czach computer org>
- Date: Fri, 8 Mar 2002 20:01:22 -0500
- References: <3C889F94.29502.2B105B@localhost>
- Sender: owner-elec-trak cosmos phy tufts edu
Actually there might be a solution (there's always a solution :-)
Way back in my pile of junk is an old DEC TC01 DecTape unit from the
1960's.
This unit used the same twist-lock plug; however it had a third round pin
in
the center.
That was the ground. My guess is Hubbel built an ungrounded version (the
one
on the ET) and one that had a hole in the center for plugs with three
prongs. As per NEC codes, one could plug an ungrounded device into a
grounded receptacle, but one could not plug a grounded device into an
ungrounded receptacle (think normal 2 and three prong outlets)
Thus if I can find one of these, I could retrofit the tractor, have my
ground (which would be nice, because someday this system will charge off
20amps of solar) and plug in ET devices when needed.
Anyone know if that outlet is fused with a 20-30 amp fuse?
Chris
----- Original Message -----
From: "David Roden (Akron OH USA)" <roden ald net>
To: "Christopher Zach" <czach computer org>
Sent: Friday, March 08, 2002 11:25 AM
Subject: Re: (ET) Tool receptacle
> On 7 Mar 2002 at 19:18, Christopher Zach wrote:
>
> > Kind of how you will not find two prong electrical outlets anymore;
> > installing one is pretty much a violation of current NEC codes.
>
> This is generally correct. Note though that in an older home with
> ungrounded wiring, NEC prohibits installation of a 3-pin outlet as a
> replacement for a defective 2-pin, unless a ground is run to the box.
There
> is some question in my mind about whether installing a 2-pin outlet is
> permitted or not -- this is unclear to me. However, in such cases the
code
> explicitly permits the installation of a GFI ~without~ ground (yes they
> do
> still function that way), provided that the outlet is labeled "no
equipment
> ground." This is what I do when replacing the outlets in my current home
> (circa 1920).
>
>
> David Roden - Akron, Ohio, USA
> 1991 Solectria Force 144vac
> 1991 Ford Escort Green/EV 128vdc
> 1970 GE Elec-trak E15 36vdc
> 1974 Avco New Idea 36vdc
> = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
> Thou shalt not send me any thing which says unto thee, "send this to all
> thou knowest." Neither shalt thou send me any spam, lest I smite thee.
> = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
>
>
>