Hi, I recently acquired a 26AE15AA that will not run and would like to get your opinions. I was told that the tractor did run when parked indoors many, many years ago. There has been some work done on this tractor in the past. From what I can see the; - Key switch has been replaced - Forward / reverse relay is a different unit completely. - Card 1 has soldered connections for the wires now vs the slip pins and all the wires were cut and reconnected via a 15 pin AMP connector. I performed some initial checks from the Home Owners Manual. - Wiring looks clean - Card components look fine - Key works - PTO works - FWD/REV relay works - All the microswitches in the speed control are good. - Voltage from the speed control start switch is getting to Card 1 pins 5 and 6 as they should depending if start was actuated in forward or reverse. However the L coil does not energize. I applied voltage externally and the coil did energize. From the looks of things, this points to a Card 1 issue but I was wondering if there is something that I may have missed. Could the resistor card be a problem? Or doesn’t that have anything to do with the energizing of the L coil? Thanks for your help. Regards, Dean A. Stuckmann 5432 County Road U Newton, WI 53063 |