[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ET) Intermittent no reverse on my E12



         On those, the most common loss of direction cause has been one of the for armature reversing contactors.Finding out which set of high current contacts that are remaining 'open' is the thrill. :)

RJ


On 7/7/2012 1:06 AM, Biophiliac wrote:
Sorry,  Jim C asked that also. It is serial#HR25633 and model is 26AE12HA. 
Jef

RJ Kanary <rjkanary consolidated net> wrote:

  What flavor of E-12 do you have? There are several. That 
information is found on a small plate in the front battery compartment.

RJ


On 7/6/2012 10:58 PM, Biophiliac wrote:
Hi all,
I'm a long time reader of this forum and have been getting some help from Jim Coate directly because I've historically been unable to post with my Android thingy and have no other on line options. Hope this works.

Among other problems,  my E12 intermittently doesn't move in Reverse. Especially after running awhile or more frequently with this record heat. I carefully removed  and swapped/switched out the reverse switch with a forward one . Didn't solve. Any ideas from those viewing this forum would be welcome.
Jef Spalding
_______________________________________________
Elec-trak mailing list
Elec-trak cosmos phy tufts edu
https://cosmos.phy.tufts.edu/mailman/listinfo.cgi/elec-trak