(ET) Problem with E20



Title: Message
I am experiencing a problem with my E20 that I am hoping someone can help me with.  My tractor seems to have only 3 speeds forward now.  I have checked the #4 card and it looks good and I have cleaned the card edge connector, etc.  The other day, the tractor stopped running altogether, no drive motor at all.  I was able to flick the f/w switch into reverse and it started to run again, as well as forward now.  Next day I decided to look into it a bit more and the tractor was dead again.  Switching to reverse didn't work this time so I unscrewed the control board panel with the relays on it and checked each relay for proper alingment etc.  When I tried motor with the control board in the down position, it started to work again.  Thought maybe I had a short somewhere that was causing this, but I cannot find one as of yet.  When I press foot pedal the motor starts speed, and then slowly move the panel up to the correct mounting position, the power cuts out again, and will not function in the mounting vertical position.  I noticed that with the foot pedal depressed slightly and the control board half way back up, the fw relay starts to chatter right before loosing all power.  Shouldn't the fw relay function for the first 3 speeds?  In troubleshooting this I also noticed that the #3 card had the varistor burned and indeed the traces were gone from it.  I tried jumpering the card accross the edge connectors that the traces lead to, but it immediately began to smoke the jumper wire when I applied power.  I have a new card from Harrold but do not want to install it until I can figure out why it is drawing so much current.  I know this really sounds like a short somewhere and will start to trace each wire as time permits.
 
 
Bob K.


The information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender and delete the material from any computer.

First Republic Bank and its subsidiaries do not take responsibility for, or accept time-sensitive instructions sent by email including orders, funds transfer instructions or stop payments on checks. All instructions of this nature must be handled by direct communication, not email.

We reserve the right to monitor and review the content of all email communications sent or received. Emails sent to or from this address may be stored in accordance with regulatory requirements.