At 09:13 PM 5/13/05 -0400, David Roden wrote:
On 12 May 2005 at 22:30, Anthony Bailey wrote:
> Could
> this actualy be a DC motor and the square box is a diode rectifier
> setup?
Very possible. My Black & Decker MM-450 corded push mower uses a brushed
PM
motor and a bridge rectifier. I think one reason is that it allows them
to
short the armature when it's shut off - the resultant plug braking means
that it stops RIGHT NOW.
Minor nit, that wouldn't be plugging. You actually drive the motor in
reverse to plug. I might hesitate to call it regenerative braking since
you don't actually regenerate into any storage. Maybe generative braking?
Robert
" 'Freedom' has no meaning of itself. There are always restrictions, be
they legal, genetic, or physical. If you don't believe me, try to chew a
radio signal. " -- Kelvin Throop, III
http://www.aeolusdevelopment.com/
_______________________________________________
Elec-trak mailing list
Elec-trak cosmos phy tufts edu
https://cosmos.phy.tufts.edu/mailman/listinfo/elec-trak