(ET) Reverse operational on E20 again



Well, this weekend I once again came to the conclusion that the Elec Trak Owner's manual is worth it's weight in gold. I used the E20 schematic to find out exactly where the wires for the D402 and D403 diodes (which power the 1A,2A,3A contactors) went and it turns out that someone mis-wired the tractor and had the wire going to D403 going to the wrong side of the wrong contactor. Thus instead of having a full 36 volts for the contractors it had only 24-25 volts; not enough to draw them in.

Moved the wire to the right post, and everything works. I even have cruise control in reverse, which is terrifying as the only way to drop out of cruise in reverse is to hit the brake or the key. In forward you can drop out by pressing the pedal down but since speeds 5-8 are inoperative, it's a bit of a problem.

Now onto the last issue: I think that the drop-out for field weakening is not working properly on my E20. Card 4 again. The little copper shunt gets *WAY* too hot, but only when I am tooling around in speeds 5-8. Thus I conclude that it's acting as a resistor but not dropping out the FW circuit.

Off to the drawing board. I should be able to figure this out next week.

Chris