[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ET) E15 goes forward/forward
On 10 Oct 2004 at 10:15, paul gilbertson wrote:
> So, now what should I check/do?
Using a voltmeter, check at the motor field terminals to make sure the
field
polarity is actually reversing when the relay pulls in. I suspect that it
isn't. If not, it could be that the relay is clicking but the contacts
are
welded. Another possibility is that the relay is somehow bypassed.
At one point, I had a replacement reverse relay I bought from Bill Gunn.
It
clicked, but didn't actually pull in.
David Roden - Akron, Ohio, USA
1991 Solectria Force 144vac
1991 Ford Escort Green/EV 128vdc
1970 GE Elec-trak E15 36vdc
1974 Avco New Idea 36vdc
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
If voting changed anything, they'd make it illegal.
-- Emma Goldman
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =