I measured the current draws of various areas
of my stationary E20 for future reference with a digital clamp-on
ammeter.
Mowing Deck only; suspended in air with
original high-lift blades = 25.5 Amps.
Main Drive
Motor, current of armature and full field, with
transmission in neutral = 11.60 Amps.
Field current alone = 2.00 Amps, Armature alone =
9.60 Amps.
Main Drive
Motor, current of armature and weakened
field, with transmission in neutral = 17.00 Amps.
Field current alone = 0.60 Amps, Armature
alone = 16.40 Amps.
Headlights = 4.00 Amps
Mowing Deck Lift Motor = 16.00 No Load. Max of 28.00 Amps to suspend
deck level. 44.00 Amps just before stall.
Test conditions...Ambient = 70F. Battery charge = Full.
Tim |