[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ET) Time to check your batteries!



Don,

 I am not sure the ring terminal is up to the job of supplying the high
amounts of current that is needed during heavy use. I originally used a
setup like you have on the web page but found that after a hour of mowing
the connectors were getting warm. I went back to the original automotive
type connector that came with the tractor. It's all a matter of cross
sectional area, the ring connectors narrow down just as they go into the
ring and that is what causes the heating. Any heating at this point is lost
power and could damage the plastic case post seal.

 I like the old connectors because the wire is leaded into the connector
body and has lots of lead around the battery post. I did have to clean and
replace all the bolts on the old connectors. I will try to get a picture of
my modification to the battery post to keep the connection tight. What I 
did
was use some ss nuts, washers and lock washers on the stud on top of the
post . The washers keep the clamp from working off the top of the post and
provide more area for current to flow. The battery connection stay nice and
cool now. If you over tighten the lead battery clamp it will deform and go
bad, but with the extra washer on the top of the post pushes the clamp down
on the post keep to keep it nice and tight.

 Any connection that gets warm/hot to the touch after using your tractor
needs to be looked at as it is wasting power and could damage something.
Your hand works very well for this test but be careful the first time, the
connection may be quite HOT..

  Dwight 




Dwight L. Hazen, Indiana University, UITS 
Bloomington, In. 47408-7378 Phone 812-855-5367 hazen indiana edu
http://php.ucs.indiana.edu/~hazen/ Ham Radio wb9tlh arrl net
NetMeeting Directory server for IU ils.iu.edu



> -----Original Message-----
> From: Don Barry [SMTP:Don Barry kmtc com]
> Sent: Monday, June 25, 2001 3:56 PM
> To:   elec-trak cosmos phy tufts edu
> Subject:      Re: (ET) Time to check your batteries!
> 
> Make that "real hot" down here in Houston..... on the battery subject,
> last night I posted up on
> http://www.elec-trak.org a FAQ (with photos) on how to convert your
> battery cables for the Universal Post batteries. According to Bill, it's
> the way to go and avoid "arc welding lessons"!
> 
> Don
> 
> Don Barry
> Infrastructure Manager, IT
> Kirby Corporation
> E-Mail: don barry kmtc com
> Phone: 713-435-1032
> Fax: 713-435-1070
> 
> >>> "Hazen, Dwight L" <hazen indiana edu> 06/25/01 03:45PM >>>
> 
> 
>  Group,
> 
>  Hot weather has made it appearance to most parts of the country now and
> ET
> activities should be in full swing. So now would be a good time to check
> your water levels and look for any loose connections.
> 
>  
> 
>   Dwight  
> 
> 
> 
> Dwight L. Hazen, Indiana University, UITS 
> Bloomington, In. 47408-7378 Phone 812-855-5367 hazen indiana edu 
> http://php.ucs.indiana.edu/~hazen/ Ham Radio wb9tlh arrl net 
> NetMeeting Directory server for IU ils.iu.edu
> 
> 
> 
>