    <p><font size="+2"><font face="Times New Roman">          My view
          from the bleachers. My deceased Dad was an industrial
          electrician for the then American Bridge Division of US Steel.
          He spent his last years of life with us. During that time, I 
          acquired my very first Elec-Trak, an E-10.</font></font></p>
    <p><font size="+2"><font face="Times New Roman">          An</font></font><font
        size="+2"><font face="Times New Roman"><font size="+2"><font
              face="Times New Roman"> I-5</font></font> and an </font></font><font
        size="+2"><font face="Times New Roman"><font size="+2"><font
              face="Times New Roman">E-20</font></font> soon followed.
          We had some good Dad & Sprout time with them. He quickly
          pointed out the similarities between the ET circuitry and the
          large DC operated overhead cranes used at the plant.</font></font></p>
    <p><font size="+2"><font face="Times New Roman">           He also
          pointed out that there was a primitive ground fault system
          using incandescent lamps to indicate that the crane and / or
          its supporting structure was HOT. All further use was halted
          until the issue was found and rectified.</font></font></p>
    <p><font size="+2"><font face="Times New Roman">            BAD
          things would happen if those warnings were ignored.</font></font></p>
    <p><font size="+2"><font face="Times New Roman">Your mileage may
          vary. :)</font></font></p>
    <p><font size="+2"><font face="Times New Roman"><br>
        </font></font></p>
    <p><font size="+2"><font face="Times New Roman">RJ</font></font><br>
    </p>
    <div class="moz-cite-prefix">On 12/2/2019 5:10 PM, Chris Zach wrote:<br>
    </div>
    <blockquote type="cite"
      cite="mid:68f87ed2-8ede-9c48-2b63-fabf62583536@alembic.crystel.com">Ok,
      so I figured the motor was not going to fix itself and took it
      apart today. Removed the huge front pulley with my 3 fingered
      pulley puller, then pressed out the armature and set it next to
      the E15 armature.
      <br>
      <br>
      Note: It's a bigger armature, no doubt.
      <br>
      <br>
      I then unscrewed the field screws on the motor (hint: Find the
      *exact* size screwdriver, clean the slots of all crud that might
      keep the screwdriver from fully engaging, put penetrating oil in,
      and use a wrench on it while putting pressure down with your
      shoulder. These heads could strip) and started thinking about how
      to get the field wires out of the plastic housing (so I could
      thread them into the motor and pull the windings out) when I
      figured I should test the motor again with my sparker.
      <br>
      <br>
      No spark at all, no ground fault. Hm.
      <br>
      <br>
      Put the screws in on one field side: No ground fault. Did the
      other, ground fault.
      <br>
      <br>
      So it looks like the fault is between one of the field halves and
      the motor body. If the screws were not ferrous that could fix the
      fault but I don't know if nylon screws are made that big and if
      they would hold under the motor's heat range. Debating if it's
      worth it to pull out the field, I could wind up breaking more of
      the insulation and making it worse. I know that the short is to
      the metal field support and not to the motor body because it will
      spark on the inside of the motor on the side that's shorted.
      <br>
      <br>
      I might be stuck here running with a ground faulted motor, or I
      could bypass the whole compensating field and just run with the
      series one. Which would be a better option?
      <br>
      <br>